IBS Passive System

Roomtop Leaky Cable HLRWUCYZ-50-12GT (1/2″)

50 Ω 1/2″ roomtop leaky cable engineered for in-building distributed coverage. Wide 170°+ radiation across cellular bands provides uniform indoor signal from ceiling installations.

Roomtop Leaky Cable HLRWUCYZ-50-12GT (1/2″) — ZTT telecom cable

Features & Characteristics

  • Radiating-mode leaky cable optimised for indoor / ceiling deployment
  • Wide 170°+ radiation angle
  • Multi-band support: 698–2200 MHz
  • Compact 1/2″ envelope suits indoor cable trays and ceiling installs
  • Low-smoke halogen-free jacket for in-building fire safety

Applications

  • Distributed antenna systems (DAS) in offices, malls and hotels
  • In-building cellular / public-safety coverage
  • Airports, stadiums and large public venues

Mechanical characteristics

Inner conductor OD
9 ± 0.3 mm
Outer copper conductor OD
13 ± 0.3 mm
Jacket
LSZH low-smoke halogen-free
Min static bending radius (single)
80 mm
Min dynamic bending radius (multiple)
125 mm
Operation temperature
-40 °C ~ +85 °C

Electrical characteristics

Radiation angle
≥ 170°
Operation frequency
698–2200 MHz
Stop band
1350–1550 MHz, 2200–2300 MHz
VSWR
< 1.35

Coupling loss (wide-angle & 0°)

Frequency (MHz)Attenuation (dB/100 m, 20 °C)Coupling loss 95 %, 2 m (dB)Wide-angle coupling loss 95 %, 2 m (dB)
7003.68289
8004.158183
9004.248285
180013.397679
200014.637577
240016.927577

Need a specification we don't list?

We source technical products on request. Send us your specification sheet and we will respond with sourcing options and lead times.