The ZTT high-strength compression tension clamp is designed for large-section AACSR and ACSR conductors used on UHV and river-crossing spans. Type testing on a 48.9 mm diameter AACSR-900/510 conductor (RTS 1192.19 kN) recorded a tensile failure at 1227.663 kN, equal to 102.98% of the conductor's rated tensile strength — the tension clamp is stronger than the conductor it terminates.

High-Strength Compression Tension Clamp — ZTT power infrastructure fitting

Features & Characteristics

  • Compression joint engineered for large-section AACSR / ACSR conductors.
  • Verified stronger than the conductor RTS in ZTT type testing (102.98% RTS on AACSR-900/510).
  • Manufactured to BS / EN / IEC 61284 with hot-dip galvanised steel bodies where applicable.
  • Suitable for UHV projects and long-span river crossings.

Applications

  • Dead-end and tension joints on UHV AC / DC transmission lines.
  • Long-span river-crossing lines using high-RTS AACSR / ACSR conductors.
  • Repair and mid-span tension joints on heavy-duty overhead lines.

Technical specifications

Type
Compression tension clamp (dead-end)
Test conductor
AACSR-900/510, OD 48.9 mm, RTS 1192.19 kN
Tensile test result
1227.663 kN — 102.98% RTS of conductor
Applicable standards
BS / EN / IEC 61284, BS 3288, IS 2486
Corrosion protection
Hot-dip galvanised (ISO 1461, ASTM A153); optional thermal-diffusion GREENKOTE

Type-test conductor (AACSR-900/510) technical structure

ParameterUnitValue
Conductor diametermm48.9
Cross sectionmm²1410.63
Conductor weightkg/km6516.68
Rated tensile strength (RTS)kN1192.19
Modulus of elasticityGPa103.73
Coefficient of linear expansion10⁻⁶ /°C15.40
Max. DC resistance at 20 °CΩ/km0.03732
Tension clamp tensile testkN1227.663 (102.98% RTS)